Integrating sphere


Changchun New Industries Optoelectronics Technology Co., Ltd. supplies standard integrating spheres alongside fully customizable versions, perfectly suited for constructing a wide range of spectral measurement systems. Cost-effective and highly versatile, these spheres can be readily fitted with matching accessories to function as uniform light sources while supporting laser power testing, spectral analysis, transmittance and reflectance measurement, among other capabilities.
Our integrating spheres adopt a multi-port configurable design, enabling fast mounting of application-specific accessories to accommodate diverse testing requirements. Simple to operate with outstanding flexibility, they support custom port sizes and positions to match unique customer setups. The inner wall is lined with a high-performance diffuse reflective coating featuring ideal Lambertian characteristics, high diffuse reflectivity and outstanding chemical stability. The coating is resistant to yellowing and delamination, guaranteeing consistent, reliable measurement performance over extended service periods.

 

 

Standard Integrating Sphere

Features

Suitable for various spectral measurements with great versatility
High-performance diffuse reflective coating with outstanding stability
Ideal Lambertian optical characteristics
Compatible with diverse accessories for flexible setup
Customizable port sizes and positions

Application

Multi-type uniform light source calibration
Reflectance & transmittance spectral characterization
Laser power detection, fluorescence quantum yield testing
Scientific experimental analysis
Product performance verification, radiometric calibration & optical alignment

 

General-Purpose Integrating Sphere Technical Specifications

 

Model

 

IS84-T

IS100-T

IS125-T

IS150-T

Diameter

φ84mm

φ100mm

φ125mm

φ150mm

Spectral range

200-2500nm

200-2500nm

200-2500nm

200-2500nm

Coating material

BaSO4 or PTFE

BaSO4 or PTFE

BaSO4 or PTFE

BaSO4 or PTFE

Coating reflectivity

95% or 97%

95% or 97%

95% or 97%

95% or 97%

Number of openings

3 (Customizable)

3 (Customizable)

3 (Customizable)

3 (Customizable)

Opening position

0°, North Pole, 90°

0°, North Pole, 90°

0°, North Pole, 90°

0°, North Pole, 90°

Opening size

1 inch (0°), 1 inch (North Pole), 1 inch (90°)

1.5 inches (0°), 1 inch (North Pole), 1 inch (90°)

1.5 inches (0°), 1 inch (North Pole), 1 inch (90°)

1.5 inches (0°), 1 inch (North Pole), 1 inch (90°)

Support structure

Pedestal

Pedestal

Pedestal

Pedestal

 

Application Examples

Fluorescence Quantum Yield Measurement

Use a power probe to measure the light source's power.

Light Transmittance Measurement

 

Laser power measurement

LED uniform light source

 
 


Customized Integrating Sphere

 

 

Type

 

Product images

Application

Gold-plated integrating sphere

 

Infrared high/low laser power measurement (use a gold-plated, water-cooled integrating sphere if the power is too high); 
Laser and laser diode output characteristic testing; 
Measurement of output characteristics of CO2 lasers and Nd:YAG lasers;

Reflectance-specific integrating sphere

 

Solid sample reflectance measurement;

Reflectance measurements of powder and thin-film samples;

Spectral reflectance measurement;

Reflectance measurement;

Diffuse reflection measurement;

Light Transmittance Dedicated Integrating Sphere

 

Solid sample transmittance measurement;

Liquid transmittance measurement;

Powder and transparent sample transmittance measurements;

Spectral transmittance measurement;

Through colorimetric determination; 
Transmission measurement;

Quantum Efficiency-Specific Integrating Sphere


 


 

Luminescence Quantum Measurement;

Specialized integrating sphere for water quality analysis

 

 

 

Water body detection and analysis;

Dedicated Integrating Sphere for Uniform Light Sources

 

For calibration of imaging systems and devices used within the laboratory;

Uniformity correction for large- and small-aperture space-based remote sensing and telemetry systems; 
Film/Digital Camera/Camcorder Uniformity Correction; 
Calibration of CCDs, uniformity of area-array detectors, and spectral response characteristics; 
Biological, low-light imaging, and quantitative measurement calibration; 
For generating uniform output of dim lighting, such as simulating starlight, moonlight, and more; 
Can be used to generate monochromatic weak light signals; 
For calibrating cameras used in low-light measurements, such as calibration of fluorescence measurement systems; 
It can be widely applied in fields such as bioimaging, pharmaceuticals, and biomedicine;

Note: The custom integrating spheres mentioned above can be tailored to meet specific user requirements, offering different spectral ranges, sizes, output beam intensities, and output aperture diameters.